DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Commands 
8-336
test eda-external-device-alrm 
8
Parameters
physical location
In addition to entering the word “physical” the system technician 
must specify the physical location. For an administered external 
device alarm analog line port, a “physical location” represents the 
physical position of the port to be tested and is entered as 
UUcSSpp where “UU” represents the cabinet number (1-MAX_
CABS), “c” represents the carrier, “SS” represents the slot position, 
and “pp” represents the circuit.
Since the “maintenance board” alarm connections connect to 
control carrier boards that are in unnumbered slots, the standard 
port format cannot be used to designate these alarm connections. 
The special ports UUmajor and UUminor are used designate the 
major or minor maintenance board alarm connection for cabinet UU.
NOTE:
The special locations 
UUmajor
 and 
UUminor
 designate the 
name of the major or minor maintenance circuit pack alarm 
connection for cabinet UU (depends upon the auxiliary 
connector of the Port Network). Thus, both a “major”  and 
“minor” port can be administered with major, minor, or 
warning alarms.
The “all” location is used to test all administered external device 
alarm ports on analog line boards and maintenance boards.
repeat number
The “number” specifies how many times the “test physical location” 
is to be repeated. “Number” may be any integer between 1 and 100.
clear
This option causes the test sequence (short or long) to repeat until 
the alarm (if one exists against the MO) is cleared or a single test in 
the sequence fails. If no alarms are registered against the 
maintenance object then the test sequence will be exercised only 
once.
schedule
When the “schedule” option is specified, the command is validated 
and then a scheduling form is displayed to allow the technician to 
schedule execution of the command. The command is then placed 
in the command queue and is executed at the specified time. The 
information displayed by the command is sent to the system printer 
instead of the screen. Refer to the Report Scheduler and System 
Printer feature specifications [1] for more details.