Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Commands 
8-337
test eda-external-device-alrm 
8
Examples
test eda-external-device-alrm all
test eda-external-device-alrm all schedule
test eda-external-device-alrm physical 1major r 10
test eda-external-device-alrm physical 2c1101 c
Output
For the following output example the command that was entered was test 
external-device-alarm all
The responses are displayed on a test-by-test basis with one line of data 
displayed for each test result.
Field definitions:
Port
The port address (cabinet-carrier-slot-circuit) of the maintenance 
object that is being tested.
Maintenance
Name
The type of maintenance object that is being tested.
Alt. Name
The alternate means of identifying the MO. This is an administered more 
descriptive name of the external device alarm
Test No
The actual test that is being executed.
Result
The result of the individual test -PASS, ABORT, FAIL,NO BOARD, 
DISABLED, EXTRA BD.
test eda-external-device-alrm all
 
                             TEST RESULTS
 
  Port      Maintenance Name  Alt. Name Test No. Result            Error Code
 
  03major   EXT-DEV           CMS1      120      PASS
  03A2102   EXT_DEV           CMS2      120      FAIL
  01major   EXT-DEV           UPS1      120      PASS
  01minor   EXT-DEV           UPS1      120      PASS
  01c1201   EXT-DEV           UPS1      120      PASS
  03A2101   EXT_DEV           CC temp   120      PASS
  01c1202   EXT-DEV           Audix1    120      PASS
  03minor   EXT-DEV           Audix2    120      FAIL
  04major   EXT-DEV           unknown   120      FAIL
 
 
Command successfully completed