Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Commands 
8-340
test fiber-link 
8
includes destructive tests. All destructive tests abort unless the fiber link is first 
busied out. The short test sequence is non-destructive and can be performed 
regardless of whether the fiber link is busied out.
A fiber link is a connection between port networks (PNs), switch nodes (SNs), or 
between a PN and the Center Stage Switch (CSS). This connection is comprised 
of a bi-directional optical fiber connection (optionally extended via a DS1 
Converter Complex), with each end terminated on either an Expansion Interface 
(EI) or a Switch Node Interface (SNI). Fiber links provide the medium for circuit 
and packet connections between PNs and for communication between the SPE 
and Expansion PNs (EPNs) for the CSS.
The long sequence includes destructive tests and requires that the fiber link be 
busied out first. When a fiber is busied out, all calls over that fiber are dropped.
clear firmware-counters clears the firmware counters of specified SNI, SNC or 
DS1C circuit packs, or of an the entire PNC (A or B).
Parameters
Examples
Simplex PNC:
test fiber-link 1 l schedule
test fiber-link 10 sh r 25 sch
Duplicated PNC:
test fiber-link 1 a-pnc schedule
test fiber-link 03 b-pnc sh r 3
Output
The following display shows a typical result when test fiber-link 1 b-pnc is 
entered.
link#
The number associated with a fiber link or fiber link pair (on duplicated 
PNCs). List fiber-link displays the location of endpoints for each fiber 
link.
a-pnc | b-pnc
On Critical Reliability systems (duplicated PNC) this identifier is used to 
distinguish between the two fibers of a duplicated fiber pair.
Port
On Critical Reliability systems (duplicated PNC) there are two fibers 
associated with every fiber link number. 
A-PNC
 and 
B-PNC
 distinguish 
one from the other.