Maintenance Commands 
8-342
test hardware-group 
8
Parameters
All maintenance objects included in the specified hardware group are tested, 
including all circuit packs and ports. When a cabinet or larger entity is specified, 
environmental MOs are tested (see test environment).
Add Station
If the add station command is entered for an untranslated port at the 
same time as it is being tested by the test hardware-group command 
with the all-ports option, the request to add station will fail and the 
following message will be displayed: 
Object in use; please try later
Trunk 
Administration
If an attempt is made to add an unadministered trunk port to a trunk 
group at the same time as it is being tested because of the test 
hardware-group command with the all-ports option, the request will 
fail and the following message will be displayed:
Object in use; please try later
Save Translation
If the test hardware-group command is issued with the all-ports 
option when a translation save operation is active, some 
unadministered ports may not be tested. All other hardware will be 
tested normally.
Hardware 
Alarms
When a hardware error is detected by the test hardware-group 
command the hardware goes through the standard escalation 
strategy. Alarms will be raised on hardware that manifest hard errors. 
This alarming strategy is the same, regardless of whether the ports 
are translated or not.
System 
Interaction
The performance of test hardware-group is affected by call 
processing traffic, administration activity, choice of the short or long 
option, whether the all-ports option was chosen, whether the 
spe-interchange option was chosen, and other demand maintenance 
activity.
Scheduled and 
Periodic 
Maintenance
When a test hardware-group command is entered, all activity related 
to scheduled background maintenance, periodic background 
maintenance, and data audits is suspended for the duration of the 
execution of the test hardware-group command. When a test 
hardware-group command is canceled or when the test 
hardware-group command completes, all suspended periodic, 
scheduled, and data audits background maintenance activity will be 
restarted where it left off.
Demand Testing 
of SPE 
Components
When a test hardware-group command is entered with the 
SPE-interchange option, demand tests of SPE components may 
abort while the interchange is in progress.