Lucent Technologies Release 7 User Manual
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Commands
8-343
test hardware-group
8
Examples
test hardware-group system
test hardware-group port-network 11
test hardware-group pnc a-pnc
test hardware-group board 01c07
test hardware-group spe
test hardware-group port-network 11
test hardware-group pnc a-pnc
test hardware-group board 01c07
test hardware-group spe
Form Input
When you enter the command, an input form is displayed upon which you can
specify certain options.
specify certain options.
Test
sequence
Specify the short or long test sequence. The long sequence is more
comprehensive and is not destructive.
comprehensive and is not destructive.
Test
Repetition
Specify repeat to enter a number of times that the entire test sequence
is to be repeated. Specify continuously to cause the test sequence to
be repeated until the command is canceled.
is to be repeated. Specify continuously to cause the test sequence to
be repeated until the command is canceled.
count
When the previous field is set to repeat, specify the number of
repetitions here.
repetitions here.
Auto-page?
Specifying y causes a whole new screen to be displayed automatically
whenever the screen fills up with results. This option is incompatible
with the background option. If you do not specify the auto-page option,
once the screen fills with results, testing will stop until you press
whenever the screen fills up with results. This option is incompatible
with the background option. If you do not specify the auto-page option,
once the screen fills with results, testing will stop until you press
Page
or
Cancel
. Specifying print on the command line automatically engages
auto-page.
Background?
Specifying y causes the tests to run in the background, freeing up the
terminal for other tasks. Error results are logged in the error log but not
displayed on the screen. This option is incompatible with the auto-page
and "continuously" options.
terminal for other tasks. Error results are logged in the error log but not
displayed on the screen. This option is incompatible with the auto-page
and "continuously" options.
Failures?
Specifying y causes only failure results to be displayed on the screen.
All-ports?
Specifying y causes testing of all customer-translated line and trunk
ports and, for the following circuit packs, untranslated ports as well:
ports and, for the following circuit packs, untranslated ports as well:
TN#
Description
TN#
Description
TN413
Digital Line [G3r V2]
TN753
Direct-Inward-Dial Trunk
TN417
Auxiliary Trunk [G3r V2]
TN754
Digital Line
TN429
DIOD Trunk [G3r V2]
TN754
Digital Line
TN436
DID Trunk [G3r V2]
TN760C
Tie Trunk
TN437
Tie Trunk [G3r V2]
TN762
Hybrid Line
TN438
Central Office Trunk [G3r V2]
TN762B
Data Line