Lucent Technologies Release 7 User Manual
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-2
ABRI-PORT (ASAI ISDN-BRI Port)
9
ABRI-PORT (ASAI ISDN-BRI Port)
Refer to BRI-PORT (ISDN-BRI Port) information for repair procedures.
MO Name (in
Alarm Log)
Alarm Level
Initial Command to Run
Full Name of MO
ABRI-PORT
1
1.
The alarm level for ABRI ports may be administered using the set options command. The
alarm level can be set independently for off-board and on-board alarms to WARNING,
MINOR, or MAJOR for all ABRI ports in the system.
alarm level can be set independently for off-board and on-board alarms to WARNING,
MINOR, or MAJOR for all ABRI ports in the system.
MAJ/MIN/WRN
test port UUCSSpp l
2
2.
UU is the universal cabinet number (1 for PPN, 2 - 44 for EPNs). C is the carrier designation
(A, B, C, D, or E). SS is the number of the slot in which the circuit pack resides (01 to 21).
pp is the two digit port number (01, 02, ...).
(A, B, C, D, or E). SS is the number of the slot in which the circuit pack resides (01 to 21).
pp is the two digit port number (01, 02, ...).
ASAI ISDN-BRI Port