Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-14
ADX8D-BD (AUDIX Circuit Pack) 
9
ADX8D-BD (AUDIX Circuit Pack)
The ADX8D-BD maintenance object represents a TN566/TN2169 DEFINITY 
AUDIX circuit pack (sometimes called Embedded AUDIX) operating in 
digital-port (DP) mode. For circuit-pack-level problems, see ‘‘XXX-BD (Common 
Port Circuit Pack)’’. Port-level problems are covered by ADX8D-PT.
DEFINITY AUDIX
 
consists of two circuit packs that occupy 5 slots on a port 
carrier. The tests described in this manual apply only to switch-side maintenance 
which tests circuit pack components related to the TDM bus interface. The 
AUDIX system has an extensive maintenance strategy that is described in 
DEFINITY AUDIX System Maintenance, 585-300-110.
MO Name (in 
Alarm Log)
Alarm Level
Initial Command to Run
1
1.
UU is the universal cabinet number (1 for PPN, 2 - 44 for EPNs). C is the carrier 
designation (A, B, C, D, or E). SS is the number of the slot in which the circuit pack 
resides (01 to 21).
Full Name of MO
ADX8D-BD
MINOR or 
WARNING
test board UUCSS sh
AUDIX Circuit Pack