Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-15
ADX8D-PT (AUDIX Digital Port) 
9
ADX8D-PT (AUDIX Digital Port)
The ADX8D-PT maintenance object represents a port on a TN566/TN2169 
DEFINITY AUDIX circuit pack (sometimes called Embedded AUDIX) operating in 
digital-port (DP) mode. The maintenance strategy for ports on the TN566 
operating in control-link mode is described in ADX16A-PT. 
The tests described in this section apply only to switch-side maintenance which 
tests circuit pack components related to the TDM bus interface. The AUDIX 
system has an extensive maintenance strategy that is described in 
DEFINITY 
AUDIX System Maintenance, 585-300-110.
AUDIX resides on a combined pair of circuit packs: the TN566 Multifunction 
Board (MFB) and the TN2169 Alarm Board (ALB). Because of its size this 
combination occupies 5 slots, but only 1 slot is functional as far as the switch is 
concerned. The other 4 slots are seen by the switch as ‘‘AUDIX-reserved’’ slots 
(or ADXDP-RS/ADX8D-RS.)
In DP mode the TN566 pack supports up to 8 voice ports, each with a primary 
information channel and a secondary information channel. Ports are 
administered in increments of two. When a call to a station with an AUDIX login is 
not answered, AUDIX answers the call using one of the available voice ports.
Unlike other AUDIX systems, DEFINITY AUDIX is not an adjunct.
!
CAUTION:
Never do any of the following without first shutting down AUDIX. Follow 
instructions on the TN566/TN2169 faceplate:
Remove DEFINITY AUDIX circuit packs
Cycle power to a carrier containing DEFINITY AUDIX circuit packs
Remove power to a carrier containing DEFINITY AUDIX circuit packs
MO Name (in 
Alarm Log)
Alarm 
Level
Initial Command to 
Run
1
1.
UU is the universal cabinet number (1 for PPN, 2 - 44 for EPNs). C is the carrier 
designation (A, B, C, D, or E). 
SS is the number of the slot in which the circuit pack 
resides (01 to 21). 
pp is the two digit port number (01, 02, ...).
Full Name of MO
ADX8D-PT
MINOR
test port UUCSSpp l
AUDIX Digital Port
ADX8D-PT
WARNING
test port UUCSSpp sh
AUDIX Digital Port