Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Architecture 
1-42
Service Codes 
1
ERL and SFRL Talking State
Echo-Return Loss (ERL) and Single-Frequency Return Loss (SFRL) performance 
is usually dominated by termination and/or loop input impedances. The system 
provides an acceptable level of echo performance if the ERL and SFRL are met.
Peak Noise Level 
Analog to analog 
 20 dBrnC (decibels above reference noise with 
C-filter)
Analog to digital 
 19 dBrnC
Digital to analog 
 13 dBrnC
Echo Path Delay
Analog port to analog port — < 3 ms
Digital interface port to digital interface port — < 2 ms 
Service Codes
Service codes (for the United States only) are issued by the Federal 
Communications Commission (FCC) to equipment manufacturers and 
registrants. These codes denote the type of registered terminal equipment and 
the protective characteristics of the premises wiring of the terminal equipment 
ports.
Private line service codes are as follows:
7.0Y — Totally protected private communications (microwave) systems
7.0Z — Partially protected private communications (microwave) systems
8.0X — Port for ancillary equipment
9.0F — Fully protected terminal equipment
9.0P — Partially protected terminal equipment
Station-to-station
ERL should meet or exceed 18 dB SFRL 
should meet or exceed 12 dB
Station to 4-wire trunk connection
ERL should meet or exceed 24 dB SFRL 
should meet or exceed 14 dB
Station to 2-wire trunk connection
ERL should meet or exceed 18 dB SFRL 
should meet or exceed 12 dB
4-wire to 4-wire trunk connection
ERL should meet or exceed 27 dB SFRL 
should meet or exceed 20 dB