Facility Interface Codes 
1
9.0N — Unprotected terminal equipment
9.0Y — Totally protected terminal equipment
The product line service code is 9.0F indicating it is terminal equipment with fully 
protected premises wire at the private line ports.
Facility Interface Codes
A Facility Interface Code (FIC) is a five-character code (United States only) that 
provides the technical information needed to order a specific port circuit pack for 
analog private lines, digital lines, MTS lines, and WATS lines.
Table 1-19
 through 
 list the FICs. Included are service order codes, 
Ringer Equivalency Numbers (RENs), and types of network jacks that connect a 
line to a rear panel connector on a carrier.
Table 1-19.
Analog Private Line and Trunk Port Circuit Packs
Circuit Pack
FIC
Service 
Order Code
Network 
Jack
TN742 and TN747B Off-Premises 
Station Port, and TN746B Off-Premises 
Station Port or On-Premises Station port
0L13C
9.0F
RJ21X
TN760/B/C/D Tie Trunk
TL31M
9.0F
RJ2GX
Table 1-20.
Digital Trunk Port Circuit Packs
Circuit Pack
 FIC
Service 
Order Code
Network 
Jack
TN1654 and TN574 DS1 Converter; TN722B 
DS1 Tie trunk; and TN767 and TN464 DS1 
Interface
04DU9B,C
6.0P
RJ48C 
and
RJ48M