Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-33
ADX16A-PT (AUDIX Analog Line/Control Link) 
9
ADX16A-PT (AUDIX Analog 
Line/Control Link)
!
CAUTION:
Never do any of the following without first shutting down AUDIX. Follow the 
instructions on the TN566/TN2169 faceplate:
Remove DEFINITY AUDIX circuit packs
Cycle power to a carrier containing DEFINITY AUDIX circuit packs
Remove power to a carrier containing DEFINITY AUDIX circuit packs
The ADX16A-PT maintenance object represents a port on a TN566/TN2169 
DEFINITY AUDIX circuit pack that is operating in control-link (CL) mode. For 
circuit-pack-level problems (ADX16A-BD or ANL-16-BD), see “XXX-BD (Common 
Port Circuit Pack)”. For port-level problems with AUDIX operating in digital-port 
mode, see ADXDP-PT/ADX8D-PT.
The tests described in this section apply only to switch-side maintenance which 
tests circuit pack components related to the TDM bus interface. The AUDIX 
system has an extensive maintenance strategy that is described in 
DEFINITY 
AUDIX System Maintenance, 585-300-110.
AUDIX resides on a combined pair of circuit packs: the TN566 Multifunction 
Board (MFB) and the TN2169 Alarm Board (ALB). Because of its size this 
combination occupies 5 slots, but only 1 slot is functional as far as the switch is 
concerned. The other 4 slots are seen by the switch as ‘‘AUDIX-reserved’’ slots.
In CL mode the TN566 pack supports up to 16 voice ports. When a call to a 
station with an AUDIX login is not answered, AUDIX answers the call using one of 
the available voice ports.
Unlike other AUDIX systems, DEFINITY AUDIX is not an adjunct.
MO Name (in 
Alarm Log)
Alarm 
Level
Initial Command to 
Run
1
1.
UU is the universal cabinet number (1 for PPN, 2 - 44 for EPNs). C is the carrier designation (A, B,
C, D, or E). SS is the number of the slot in which the circuit pack resides (01 to 21). pp is the two
digit port number (01, 02, ...).
Full Name of MO
ADXCL-PT or 
ADX16A-PT
MINOR
test port UUCSSpp l
AUDIX Analog Line/ Control Link
ADXCL-PT or 
ADX16A-PT
WARNING
test port UUCSSpp sh
AUDIX Analog Line/ Control Link