DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-34
ADX16A-PT (AUDIX Analog Line/Control Link) 
9
Error Log Entries and Test to Clear Values
Notes:
a. This is an in-line error and can only be resolved over time. This indicates 
that no terminal equipment was present when ringing was attempted. 
Execute the short test port UUCSSpp command.
b. The circuit pack has been logically administered but not physically 
installed. The alarm will be cleared when the circuit pack is installed.
c. The circuit pack has been removed or has been insane for more than 
11-minutes. To clear the error, reseat or replace the circuit pack.
d. This is an in-line error and can only be resolved over time. This error 
indicates that ringing voltage is absent. If only one analog circuit pack in 
the system has this problem, then replace the circuit pack. If only analog 
circuit packs on a particular carrier have this error, then the ringing 
generator may not be connected to this carrier. If analog circuit packs on 
many carriers have this error, check the ringing generator.
e. AUDIX is not available to the switch. Check the AUDIX system, referring to 
DEFINITY AUDIX System Maintenance, 585-300-110.
f. The TDM bus is out of service. See the “TDM-BUS” section.
Table 9-12.
DEFINITY AUDIX Analog Line/Control Link Error Log Entries
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test port UUCSSpp sh r 1
1 (a)
40977
None
18
0
busyout station 
<
extension>
WRN
ON
release station <
extension>
23 (b)
0
None
WRN
OFF
130 (c)
None
WRN
ON
test port UUCSSpp sh
257 (d)
40973
None
513 (e)
Any
None
1025 (f)
Looparound Test 
(#161)
MIN/ 
WRN
2
2.
Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the
set options command. 
ON
test port UUCSSpp l r 2
1281
Conference Test 
(#7)
MIN/ 
WRN
2
ON
test port UUCSSpp l r 2
1537
NPE Crosstalk 
Test (#6)
MIN/ 
WRN
2
ON
test port UUCSSpp l r 2