Maintenance Object Repair Procedures
9-34
ADX16A-PT (AUDIX Analog Line/Control Link)
9
Error Log Entries and Test to Clear Values
Notes:
a. This is an in-line error and can only be resolved over time. This indicates
that no terminal equipment was present when ringing was attempted.
Execute the short test port UUCSSpp command.
Execute the short test port UUCSSpp command.
b. The circuit pack has been logically administered but not physically
installed. The alarm will be cleared when the circuit pack is installed.
c. The circuit pack has been removed or has been insane for more than
11-minutes. To clear the error, reseat or replace the circuit pack.
d. This is an in-line error and can only be resolved over time. This error
indicates that ringing voltage is absent. If only one analog circuit pack in
the system has this problem, then replace the circuit pack. If only analog
circuit packs on a particular carrier have this error, then the ringing
generator may not be connected to this carrier. If analog circuit packs on
many carriers have this error, check the ringing generator.
the system has this problem, then replace the circuit pack. If only analog
circuit packs on a particular carrier have this error, then the ringing
generator may not be connected to this carrier. If analog circuit packs on
many carriers have this error, check the ringing generator.
e. AUDIX is not available to the switch. Check the AUDIX system, referring to
DEFINITY AUDIX System Maintenance, 585-300-110.
f. The TDM bus is out of service. See the “TDM-BUS” section.
Table 9-12.
DEFINITY AUDIX Analog Line/Control Link Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
1
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test port UUCSSpp sh r 1
1 (a)
40977
None
18
0
busyout station
<
<
extension>
WRN
ON
release station <
extension>
23 (b)
0
None
WRN
OFF
130 (c)
None
WRN
ON
test port UUCSSpp sh
257 (d)
40973
None
513 (e)
Any
None
1025 (f)
Looparound Test
(#161)
(#161)
MIN/
WRN
WRN
2
2.
Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the
set options command.
set options command.
ON
test port UUCSSpp l r 2
1281
Conference Test
(#7)
(#7)
MIN/
WRN
WRN
2
ON
test port UUCSSpp l r 2
1537
NPE Crosstalk
Test (#6)
Test (#6)
MIN/
WRN
WRN
2
ON
test port UUCSSpp l r 2