Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-44
ANL-16-L (16-Port Analog Line) 
9
ANL-16-L (16-Port Analog Line)
The circuit packs listed below provide 16 analog line ports for single-line voice 
terminals. The table below indicates which circuit packs are equipped with 
lightning protection (for off-premises, out-of -building stations), and which ones 
support the neon message waiting lamp feature.
No maintenance of the terminal connected to the 16-Port Neon Analog Line 
circuit pack is performed, except to determine whether or not the terminal is 
connected. Failures of the neon message waiting lamp power and the common 
ringing application circuitry are reported as part of common port circuit pack 
errors; see errors 1281 and 1793 in the “XXX-BD (Common Port Circuit Pack)” 
section.
Ringing Caused by Maintenance Testing
Test #48 may cause some terminal equipment to ring briefly during daily 
maintenance. If this ringing is disturbing the customer or the terminal equipment, 
it should be disabled in the 
Tests
 field of the change station extension form. Be 
aware that this action will also disable Tests #6, 7, 161 and 35.
MO Name (in 
Alarm Log)
Alarm Level
Initial Command to 
Run
1
1.
UU is the universal cabinet number (1 for PPN, 2 -44 for EPNs). C is the carrier
designation (A, B, C, D, or E). SS is the number of the slot in which the circuit pack resides
(01 to 21). pp is the two digit port number (01, 02, ...).
Full Name of MO
ANL-16-L
MIN
test port UUCSSpp l
16-Port Analog Line
ANL-16-L
WRN
test port UUCSSpp sh
16-Port Analog Line
16-Port Analog Line Circuit Packs
Circuit 
Pack
Off- 
Premises
Neon
TN468B
y
TN479
TN746
y
TN746B
y
y
TN2135
y
TN2144
y
TN2149
y
TN2180
y