Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-46
ANL-16-L (16-Port Analog Line) 
9
Aux Data 40975 indicates that the terminal equipment was on-hook when 
ring-tip was detected during ringing. This usually indicates a failure in the 
terminal equipment or the type of terminal has a low ringer impedance. 
Call the terminal equipment and verify that the terminal rings. If the 
terminal does not ring, then replace it. Otherwise, issue the test port 
UUCSSpp
 command, and follow the procedure for Test #48.
Aux Data 40977 indicates that no terminal equipment was connected 
when ringing was attempted. Run the short test via the test port 
UUCSSpp
 command, and follow the procedure for the results of Test #48.
b. This is a software audit error that does not indicate any hardware 
malfunction. Run Short Test Sequence and investigate associated errors.
c. This error type indicates that the circuit pack has been removed or has 
been insane for more than 11-minutes. To clear the error, reseat or replace 
the circuit pack.
d. This is an in-line error and can only be resolved over time. This error 
indicates that ringing voltage is absent. If only 1 analog circuit pack in the 
system has this problem, then replace the circuit pack. If only analog 
circuit packs on a particular carrier have this error, then the ringing 
generator may not be connected to this carrier. If analog circuit packs on 
many carriers have this error, then it is probably a problem with the ringing 
generator.
e. Test #48 may cause some terminal equipment to ring briefly during daily 
maintenance. If this disturbs the customer or the terminal equipment, 
disable it by setting the 
Tests
 field on the change station extension form 
to 
n
. On some software releases, this will also disable Tests #6, 7, 161, 
and 35.
System Technician-Demanded Tests: Descriptions 
and Error Codes
Always investigate tests in the order presented in the table below whe
inspecting errors in the system. By clearing error codes associated with the 
Battery Feed Test, for example, you may also clear errors generated from other 
tests in the testing sequence.