Lucent Technologies Release 7 User Manual

Page of 2657
Hardware Configurations 
2-1
Multi-Carrier Cabinet 
2
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
2
Hardware Configurations
The DEFINITY System supports a variety of configurations consisting of a PPN 
and up to 21 EPNs. In addition, the system may use a Center Stage Switch (CSS) 
consisting of one or two Switch Nodes. This chapter describes the PPN and EPN 
cabinets, and the configuration of carriers and circuit packs within these 
cabinets.
Multi-Carrier Cabinet
The Multi-Carrier Cabinet (J58890A) accommodates from one to five circuit pack 
carriers, and is always used for the PPN. EPNs may use either multicarrier 
cabinets or single-carrier cabinets.
The power unit in the bottom of the MCC cabinet supplies AC voltage or DC 
voltage from an external source to the power supply in each carrier. The AC 
powered cabinet optionally contains a battery charger and backup batteries to 
provide temporary power to the cabinet if the external source fails. The backup 
unit is optional for systems powered from an Uninterruptible Power Supply (UPS). 
The fan unit in the middle of the cabinet cools the carriers. AC-powered cabinets 
have two 120V AC receptacles in the back for use as an AC power source. These 
can be used to power the G3-MT.
Each cabinet must be connected to one of the following dedicated power 
sources:
120V AC 60 Hz at 50A from a National Electrical Manufacturing 
Association (NEMA) 5-50R power outlet or equivalent
Single phase 240V AC, or three phase 208V AC, 60 Hz at 30A from a 
NEMA L 14-30R power outlet or equivalent