Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-60
ANL-24-L (24-Port Analog Line) 
9
ANL-24-L (24-Port Analog Line)
The 24-Port Analog Line circuit pack (TN793)  provides 24 ports for voice 
terminals and supports both on-premises and off-premises analog voice 
terminals.
No maintenance of the terminal connected to the 24-Port Neon Analog Line 
circuit pack is performed, except to determine whether or not the terminal is 
connected. Failures of the neon message waiting lamp power and the common 
ringing application circuitry are reported as part of common port circuit pack 
errors. See errors 1281 and 1793 in the “XXX-BD (Common Port Circuit Pack)” 
section.
NOTE:
This analog line circuit pack supports analog data modules. When 
assigned, analog data modules provide access to the Net Pkt (TN794) data 
ports. To activate an analog data module you must assign the port location 
on the data form and connect a modem to the port. (The analog data 
module may be used for connection to a CDR output or other adjuncts as 
needed.) These ports are tested the same as all other analog ports on the 
circuit pack.
Ringing Caused by Maintenance Testing
Test #48 may cause some terminal equipment to ring briefly during daily 
maintenance. If this ringing is disturbing the customer or the terminal equipment, 
it should be disabled in the 
Test?
 field of the change station extension form. Be 
aware that this action also disables Tests #6, 7, 161, and 35.
MO Name (in 
Alarm Log)
Alarm Level
Initial Command to 
Run
1
1.
UU is the universal cabinet number (1 for PPN, 2 -44 for EPNs); C is the carrier 
designation (A, B, C, D, or E); SS is the number of the slot in which the circuit pack resides 
(01 to 21); and pp is the two digit port number (01, 02, ...).
Full Name of MO
ANL-24-L
MIN
test port UUCSSpp l
24-Port Analog Line
ANL-24-L
WRN
test port UUCSSpp sh
24-Port Analog Line