DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-61
ANL-24-L (24-Port Analog Line) 
9
Error Log Entries and Test to Clear Values
Notes:
a. These are in-line errors and can only be resolved over time. 
Aux Data 40960 indicates that too many simultaneous incoming ringing 
attempts were made on this board. Only 4 ports on a board may ring 
simultaneously. A 5th incoming call will cause an inline error from the 
board.
Aux Data 40975 indicates that the terminal equipment was on-hook when 
ring-tip was detected during ringing. This usually indicates a failure in the 
terminal equipment or the type of terminal has a low ringer impedance. 
Table 9-26.
24-Port Analog Line Error Log Entries
 
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the 
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test port UUCSSpp sh r 1
1(a)
40960 
40975 
40977
none
15(b)
Any
Audits and 
Updates Test (#36)
18
0
busy-out station 
extension
WRN
ON
release station 
<extension>
130(c)
None
WRN
ON
test port UUCSSpp sh
257(d)
40973
none
513(e)
Station Present 
Test (#48)
WRN
OFF
test port UUCSSpp sh r 2
769
Battery Feed Test 
(#35)
MIN/ 
WRN
2
2.
Minor alarms on this MO may be downgraded to Warning alarms based on the values used in the set 
options
 command.
ON
test port UUCSSpp sh r 2
1025
Looparound Test 
(#161)
MIN/ 
WRN
2
ON
test port UUCSSpp l r 2
1281
Conference Test 
(#7)
MIN/ 
WRN
2
ON
test port UUCSSpp l r 2
1537
NPE Crosstalk Test 
(#6)
MIN/ 
WRN
2
ON
test port UUCSSpp l r 2
Continued on next page