Lucent Technologies Release 7 User Manual

Page of 2657
DEFINITY Enterprise Communications Server Release 7 
Maintenance for R7r  
555-230-126  
Issue 4
June 1999
Maintenance Object Repair Procedures 
9-288
AUX-TRK (Auxiliary Trunk) 
9
AUX-TRK (Auxiliary Trunk)
The TN763B/C/D and TN417 Auxiliary Trunk circuit packs are used to provide 
ports for the following features: Music-On-Hold, loudspeaker paging (voice and 
coded chimes), dictation, automated wake-up with AUDICHRON. 
Recorder/Announcer, and recorded announcements. TN763C circuit packs 
support Mu-law companding. TN417 circuit packs support A-law companding. 
TN763D can support either companding mode and defaults to mu-law on 
initialization. Companding modes are administered on the country-options 
system-parameters screen. See 
DEFINITY Enterprise Communications Server 
Release 5.4 Administration and Feature Description.
Music-On-Hold is administered via the Feature-Related System Parameters 
Form. Loudspeaker paging can be administered via the change paging 
loudspeaker
 or add trunk-group [Customer-Provided Equipment (CPE)] 
commands. The change paging loudspeaker command is used for 
system-provided paging; the add trunk group command is used for access to 
otherwise-provided (CPE) paging. The translation for code chiming is 
administered by the change paging code-calling-ids command. Recorded 
announcement and dictation are administered by the add trunk-group (CPE) 
command. Automatic wake-up is administered by the change 
system-parameters hospitality
 command and uses all four ports on a TN763B 
Auxiliary Trunk circuit pack.
Music-On-Hold provides audible feedback to a held, parked, or otherwise 
split-away party indicating that the call is still connected. The feedback can be 
customer-provided music, a recorded message, or other audible indication. 
Since the Music-On-Hold port is always busy, some of its port tests always abort.
The Loudspeaker Paging feature provides voice and/or code calling chime 
paging. If multiple paging zones are provided at a customer’s premises, the 
Loudspeaker Paging feature gives a user the option of paging to a particular 
MO Name (in 
Alarm Log)
Alarm Level
Initial Command to Run
1
1.
UU is the universal cabinet number (1 for PPN, 2 - 44 for EPNs). C is the carrier
designation (A, B, C, D, or E). 
SS is the number of the slot in which the circuit pack
resides (01 to 21). 
pp is the two digit port number (01, 02, ...).
Full Name of 
MO
AUX-TRK
MAJOR
2
2.
A Major alarm on a trunk indicates that alarms on these trunks are not downgraded by
the set options command and that at least 75 % of the trunks in this trunk group are
alarmed.
test port UUCSSpp l
Auxiliary Trunk
AUX-TRK
MINOR
test port UUCSSpp l
Auxiliary Trunk
AUX-TRK
WARNING
test port UUCSSpp sh
Auxiliary Trunk