9-290
AUX-TRK (Auxiliary Trunk) 
9
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 1 with Aux Data 57481 indicates a port fault. Use an empty port 
if one is available until the circuit pack can be replaced.
b. Error Type 1 or 769 with Aux Data 57482 indicates a fault on signaling 
lead, which is an off-board error. This error should only occur with 
loudspeaker paging. If the trunk is being used for another application, 
check that the administration is correct. Otherwise, check the wiring to the 
external equipment connected to the Auxiliary Trunk and check the 
external equipment.
c. This is a software audit error that does not indicate any hardware 
malfunction. Run Short Test Sequence and investigate associated errors.
d. Indicates the circuit pack has been removed or has been insane for more 
than 11-minutes. To clear the error, reseat or replace the circuit pack.
Table 9-131.
Auxiliary Trunk Error Log Entries 
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0
1
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
0
Any
Any
Any
test port UUCSSpp sh r 1
1(a)
57481
None
1(b)
57782
15(c)
Any
Audit Update Test (#36)
18
0
busyout port UUCSSpp
WARNING
OFF
release port UUCSSpp
130(d)
None
WARNING
ON
test trunk <grp>/<mbr> sh
769(b)
57482
None
257
Hybrid/Conference
MIN/WRN
2
2.
Major or Minor alarms may be downgraded to Warning alarms based on the values used in the set
options
 command.
ON
test port UUCSSpp l r 3
Circuit Test (#33)
513
NPE Crosstalk Test (#6)
MIN/WRN
2
ON
test port UUCSSpp l r 3
1025
Diagnostic Test
Auxiliary Trunk Test 
(#114)
WARNING
ON
test port UUCSSpp sh r 3