Configuring the 6300 Control System
The 6300 control system requires higher power than other 240V systems. Dip switch #10 is factory set in the 
ON position. This causes the heater to shut off when any pump is running in high speed. To allow the heater 
to continue operating, dip switch #10 must be set to the OFF position.
To  ensure  your  spa  functions 
properly,  ensure  the  following 
steps  are  performed  before 
starting your spa:
When installing the electrical 
• 
system, use a 60 amp GFCI. 
Follow  the  GFCI  wiring 
diagram on the next page.
Have your dealer or installer 
• 
set  dip  switch  #10  to  the 
OFF  position  on  the  circuit 
board as shown at right.
Electrical Installation for 11 kW Heater
This  applies  to  Ultimate  Fitness  spas  with  the  11  kW  heater 
only.
Two electrical services are required to heat the swim side of the 
Fitness Spa.