Topcon GTS-825A User Manual

Page of 144
5-4   
   5 PROGRAM MODES
5
Press [F6](SET) key.
Coordinate of P1 will be displayed.
[F6]
6
Press [F5](YES) key.
Coordinate of P1 will be decided.
[F5]
The display return to main menu.
Turn power off and move instrument to P1 
( Prism P1 move to P0).
Power off 
Move to 
P1
7
After the instrument is set up at P1, turn 
power on and be measurement possible.
Power on 
Select 
program
8
Press [F2](STORE) key.
[F2]
9
Press [F2](Recall NEZ) key.
10
Collimate P
0
, the former instrument point.
[F2]
Collimate 
P
0
11
Press [F5](YES) key.
[F5]
The coordinates at P1 and direction angle 
toward P
0
 are set.
The display return to main menu.
12
Repeat the procedure 
~
11
  as much as you 
wish.
*1)To reset the instrument height or prism height, press [F5](HT) key.
Store NEZ
 N :   123.456 m          
 E :    12.345 m
 Z :     1.234 m
SET OK?        YES    NO
 
          Complete
Programs
F1 BS     p                 4/7
F2 STORE  p
F3 REM    p
F4 MLM    p           MORE
Retaining a Coordinate
1.Store NEZ
2.Recall NEZ
Recall NEZ   
  HR: 300°10'20" 
Set OK?
                    YES   NO
 
          Complete