Topcon GTS-825A User Manual

Page of 144
5-5
   5 PROGRAM MODES
5.3
Remote Elevation measurement (REM)
To obtain elevation of the point at which setting the target prism is not possible, place the prism at any 
point on the vertical line from the target then carry out REM procedure as follows.
1) With prism height (h) input (Example :h=1.5m) 
Operating procedure
Operation
Display
1
Press [F3](REM) key.
[F3]
2
Press [F1](YES) key.
[F1]
3
Enter prism height, press [ENT] key.
Enter 
P.HT
[ENT]
4
Collimate prism .
Collimate 
P
5
Press [F1](MEAS) key.
Measuring starts.
[F1]
Target K
Prism  P
Prism height
G
Instrument
VD
Programs
F1 BS     p             4/7
F2 STORE  p
F3 REM    p
F4 MLM    p            MORE
REM
Prism height
1.YES
2.NO           
REM
(1)Prism Height
  P.h :          m
           
EXIT                   BS
REM
(2)Horizontal Distance
  HD :           m
           
MEAS                   SET
REM
(2)Horizontal Distance
  HD *       < m
           