4.  Wearing safety glasses, drain tank of any remaining air pressure by pulling the 
ring on the safety valve. Use other hand to deflect any fast moving air that may be 
directed towards your face.
5.  Store compressor in a cool, dry place. 
Maintenance
 
Disconnect power source then release all pressure from the  
  system before attempting to install, service, relocate or 
perform any maintenance. Service should be performed by an authorized service 
representative.
The compressor should be checked often for any visible problems and the 
following maintenance procedures should be performed each time the compressor is 
used.
ASMe SAFety VALVe
  Do not remove or attempt to adjust the safety valve!
Check the safety valve by performing the following steps: 
1.  Plug the compressor in and run until shut off pressure is reached (see Operating 
Procedure). 
2.  Wearing safety glasses, pull the ring on the safety valve to release pressure from 
compressor tank. Use your other hand to deflect fast-moving air from being 
directed toward your face.
3.  The safety valve should automatically close at approximately 40-50 psi. If the safety 
valve does not allow air to be released when you pull on the ring, or if it does not 
close automatically, it MUST be replaced. 
DrAIn tAnk
1.  Turn compressor off at foot pedal switch.
2.  Check air pressure in tank. To properly drain tank of condensation, tank pressure 
should be between 20-60 psi. Drain system will not work if there is no pressure in 
the tank. If tank pressure is above 60 psi, decrease pressure in tank by pulling the 
ring on the safety valve. Burst of air will be audible. 
3.  Slowly turn easy drain knob, located below the tank gauge, to the left 
(counterclockwise) until fluid begins to fill drain cup. Watch draining to make sure 
drain cup does not overflow. If there is a lot of fluid in the tank, you may need to 
close drain knob by turning fully to the right (clockwise) then remove the drain cup 
to dispose of fluid.
4.  When fluid stops draining, close drain knob by turning all the way to the right 
(clockwise).
5.  Lift cup up and pull out to dispose of drained fluid. Reinsert cup, making sure to 
secure in place.
CLeAnIng
Turn power OFF and clean dust and dirt from motor, tank, and air lines.
15
WL6700 Series
www.chpower.com
Operation (Continued)
Figure 18 - Safety valve
Figure 19 - Draining tank
Tank Pressure 
Gauge
Easy-Drain 
Knob
Easy-Drain Cup
Fill Line