Campbell Hausfeld WL6700 Series User Manual

Page of 68
16
Operating Instructions and Parts Manual
www.chpower.com
Maintenance (Continued)
IMPORTANT: Unit should be located as far from spraying area 
as hose will allow to prevent over-spray from entering the pump.
AIr FILter
Check air filter to be sure it is clean. To service the air filter, tip 
the unit back, resting the wheels and handle on the floor (See 
Figure 20)
. Remove the filter housing cover. Remove filter and 
blow off dirt. Replace air filter if it can not be cleaned. Place filter 
back in the housing base. Replace cover.
LubrICAtIon
This is an oilless type compressor requiring no lubrication.
therMAL oVerLoAD ProteCtor
 
This compressor is equipped with an automatic 
  reset thermal overload protector which will shut 
off motor if it becomes overheated.
If thermal overload protector shuts motor OFF frequently look 
for the following causes:
1.  Low voltage
2.  Lack of proper ventilation
 
If the thermal overload protector is actuated, 
  the motor must be allowed to cool down before 
startup is possible. The motor will automatically restart without 
warning if left plugged into electrical outlet and unit is turned on.
torque requIreMentS
Piston Bolt . . . . . . . . . . . . . . . . . . . . . . . 350 - 450 in. Ibs.
Head Bolts . . . . . . . . . . . . . . . . . . . . . . . 90 - 120 in. Ibs.
teChnICAL SerVICe
For information regarding the operation or repair of this 
product, please call 1-800-543-6400.
Figure 20 - Air Filter
Air Filter