Campbell Hausfeld HL5404 User Manual

Page of 36
Pressure switch - Auto/Off Switch - In 
the aUtO position, the compressor 
shuts off automatically when tank 
pressure reaches the maximum preset 
pressure. In the OFF position, the 
compressor will not operate. This switch 
should be in the OFF position when 
connecting or disconnecting the power 
cord from the electrical outlet or when 
changing air tools.
Regulator - The regulator controls 
the amount of air pressure at the 
hose outlet. Turning regulator knob 
clockwise (to the right) will increase  air 
pressure at the outlet. Turning knob 
counterclockwise (to the left) will lower 
air pressure to the outlet. Turning knob 
fully counterclockwise will shut off flow 
of air completely. 
asMe safety valve - This valve is 
attached to the pressure switch. It will 
automatically releases air if the tank 
pressure exceeds the preset maximum.
exhaust tube - This tube carries 
compressed air from the pump to the 
check valve. This tube becomes very hot 
during use. To avoid the risk of severe 
burns, never touch the exhaust tube.
Check valve  - This valve is located at 
the end of the exhaust tube where it 
meets the tank. It is a one-way valve 
that allows air to enter the tank, but 
prevents air in the tank from flowing 
back into the compressor pump.
handle - Designed to move the 
compressor.
 
Never use the 
  handle on wheeled 
units to lift the unit completely off the 
ground.
Drain valve - This valve is located on 
the bottom of the tank. Use this valve 
to drain moisture from the tank daily to 
reduce the risk of corrosion.
Pressure Gauges - These gauges will 
show air pressure in the compressor 
tank and at the compressor outlet.
3
hL5403, hL5404
Glossary of terms
Outlet Pressure Gauge - Will show 
air pressure at the outlet in pounds per 
square inch (psi). Make sure this gauge 
reads ZERO (by adjusting regulator 
knob fully counterclockwise) before 
changing air tools or disconnecting air 
hose from outlet.
tank Pressure Gauge - Will show air 
pressure in tank while the compressor 
is running, indicating compressor 
is building pressure properly. This 
gauge will show maximum pressure 
of compressor when it shuts off 
automatically at the pressure switch.
Motor Reset - (not shown, located 
inside motor). Designed to keep the 
motor from overheating. The motor has 
an auto reset protector. To reset once 
the motor has cooled, turn the pressuer 
switch to the OFF position, then to the 
AUTO position.
 
This compressor is  
  equipped with an 
overload protector which will shut off 
motor if it becomes overloaded.
 
If the overload  
  protector is 
actuated, the motor must be allowed 
to cool down for approximately 30 
minutes before it will reset.
Installation
LOCatIOn
It is extremely important to install the 
compressor in a clean, dry, and well 
ventilated area. The compressor must 
be placed on a firm, level surface where 
the surrounding air temperature will 
not be more than 100°F.
A minimum clearance of 18 inches 
between the compressor and a wall is 
required because objects could obstruct 
air flow.
 
Do not locate the 
  compressor air inlet 
near steam, paint spray, sandblast areas 
or any other source of contamination. 
This debris will damage the motor.
eLeCtRICaL InstaLLatIOn 
 
All wiring and   
  electrical 
connections should be performed by a 
qualified electrician. Installation must 
be in accordance with local codes and 
national electrical codes.
Handle
Outlet 
Pressure 
Gauge
Exhaust 
Tube
Oil Sight 
Gauge
Oil Drain Plug
Air Filter
Regulator
Tank Pressure 
Gauge
Pressure Switch
Figure 1 - Unit Identification