Datalogic Scanning 1000 User Manual

Page of 62
Matrix-1000™ 
22  
 
2.4 USER 
INTERFACE 
 
 
RS232 PC-side connections 
1
 
 
9-pin male connector 
13 
25
14
1
 
 
25-pin male connector 
Pin Name Pin 
Name 
2 RX 3 
RX 
3 TX 2 
TX 
5 GND 7 
GND 
7 RTS 4 
RTS 
8 CTS 5 
CTS 
 
 
How To Build A Simple Interface Test Cable: 
The following wiring diagrams show a simple test cable including power, external 
(push-button) trigger and PC RS232 COM port connections. Test Cable for Matrix-
1000™  
 
 
25-pin D-sub female
23
 
20
 
GND
 
RXAUX
 
TXAUX
 
21
 
MATRIX-
1000™ 
25
 
13
 
GND
 
VS
 
9-pin D-sub female 
GND
 
TX
 
RX
 
PC
 
2
 
3
 
5
 
18
 
9
 
EXT TRIG+
VS
 
Power Supply
VS  (10 – 30 VDC)
Power GND
 
Trigger 
EXT TRIG-
 
19
 
 
Figure 22- Test Cable