An anti-disturbance filter (debouncing) is implemented on the input, and is software 
programmable. The
 
input active state can be defined by the user as well. Refer to the 
digital I/O folder in the VisiSet™ Help On Line for further details. 
 
 
2.3.5 Outputs 
 
One optocoupled general purpose output is available on the 25-pin connector. The 
pinout is the following: 
 
Pin Name 
Function 
16 
OUT3+ 
Configurable digital output 3 - positive pin 
17 
OUT3- 
Configurable digital output 3 - negative pin 
 
It is typically used to signal the data collection result. It can also be used to control an 
external lighting system 
 
The idle state, the activation/deactivation events and the other configuration 
parameters can be defined by the user. Refer to the Digital I/O folder in the VisiSet™ 
Help On Line for further details. 
 
 
 
MATRIX
USER INTERFACE
Vext 30 Vdc max
+
-
Load
Out
 
Figure 21 - Open Collector Output Connection 
 
 
The electrical features of the output are the following: 
 
OUTPUT I
Load
 
V
Out
 
Open 
0 mA 
30 Vdc Max 
Closed 
10 mA 
1.8 Vdc Max 
P
D
 = V
Out  
×
 I
oLoad
  = 170 mW Max.