Avaya 8400B Plus User Manual

Page of 198
Isolating Problems Using Loopback Data Tests
D-8
Issue 2   November 1996
The system responds with:
OK
To halt the test, type:
AT&T0 
The system responds with the error count, then the completion signal:
OK
Remote Loopback Test with 
Self-Test
This test evaluates the quality of the data transmission channel, and the proper 
operation of the local and remote 8400B Plus Data Modules. During this test, 
the local data module generates test characters and transmits these to the 
remote endpoint, where they are looped back to the 8400B Plus Data Module. 
At the end of the test, the 8400B Plus Data Module displays a three-digit 
number indicating the number of errors that occurred during the test. Failing this 
test does not necessarily indicate a defective data module. It may instead 
indicate a problem in the communication channel or the remote endpoint. If you 
receive an error count other than zero, perform the Local Loopback Test with 
Self-Test to isolate the source of the problem — either the local 8400B Plus 
Data Module, the communications channel, or the remote endpoint.
The remote DCE must be configured to loop the characters back to the 8400B 
Plus Data Module. If the remote endpoint is an 8400B Plus Data Module, its 
user must issue an 
AT&T4
 command. This provisions the data module to accept 
a remote loopback request. If the remote data module does not respond to the 
Remote Loopback Test request, the test request will be aborted.
NOTE:
A data call must be in progress for this test.