Loop-Around Data Test Arrangement
Issue 2   November 1996
D-13
modem pool group to be tested. Separate telephone numbers should be 
administered for the Loop-Around Data Test Arrangements used for modem 
pool testing.
The 8400B Plus Data Module must be connected to the PBX and powered up 
prior to using it in the Loop-Around Data Test Arrangement. Connect an 
asynchronous data terminal to the 8400B Plus Data Module using the standard 
EIA Connector cord and supplied M9/F25 Adapter. The speed of the terminal 
should be set as indicated in 
.
Once the data rate has been set on the terminal, type the following command:
AT&FS0=1E0Q1&W0&W1 
Also set the correct installation options by typing the appropriate command:
If the 8400B Plus Data Module is the US Configuration, type:
ATS24=1 
If the 8400B Plus Data Module is the International Configuration, type:
ATS24=3 
Table D-1.
Setting Data Terminal Speed 
Access
Set Terminal Data Rate To
Direct
19200 bps
Through a modem pool that supports 
speeds of:
300 and 1200 bps
300, 1200, and 2400 bps
1200, 2400, 4800, and 9600 bps
4800 and 9600 bps
1200 bps
2400 bps
9600 bps
9600 bps
ENTER
ENTER
ENTER