Avaya 8400B Plus User Manual

Page of 198
Isolating Problems Using Loopback Data Tests
D-14
Issue 2   November 1996
You should now disconnect the terminal from the 8400B Plus Data Module. The 
8400B Plus Data Module will retain the option settings during power removal.
A loopback plug must now be connected to the EIA Connector Interface of the 
8400B Plus Data Module. A loopback plug connects pin number 2 to pin 
number 3 on the 8400B Plus Data Module’s EIA Interface using a modified 9-pin 
connector. The modified connector is shown in 
Figure D-9. 9-Pin Connector Wired as a Loopback Plug
Using the Loop-Around Data Test 
Arrangement
The user calls the Loop-Around Data Test Arrangement from a terminal/PC. 
Once connected, the user checks to see if characters entered from the 
keyboard are successfully echoed back. If the terminal/PC is set for full duplex 
and the user types in
The cat
then
The cat
is echoed back in a successful test.