Datalogic Scanning DS4600A User Manual

Page of 63
DS4600A 
2.3.1 Power 
Supply 
 
Power can be supplied to the scanner through the pins provided on the 25-pin 
connector used for communication with the host (Figure 6): 
 
 
DS4600A 
13 
25 
VS 
GND 
CHASSIS 
Earth Ground
USER INTERFACE 
CHASSIS
GND 
V+  (10 - 30 Vdc) 
 
Figure 6 - Power Supply Connections 
 
or through the jack connector on the side of the 25-pin connector for connections to a 
UL Listed Direct Plug-in Power Unit (Figure 7). If the jack input is used to supply 
power to the DS4600A, pin 13 is automatically disconnected; the supply voltage for 
the external trigger remains on pin 9. The plug connector is not supplied with the 
DS4600A. 
 
 
V+ (10 - 30 Vdc)
Jack
Plug
GND
 
Figure 7 - Power Supplied Using the Jack Connector 
 
For Standard models, the power must be between 10 and 30 Vdc only. There is a 
current peak of about 1A at 10 V during power on caused by the motor starting. 
 
For Integrated Heater models, the power must be 24Vdc only. 
 
It is recommended to connect pin 1 (CHASSIS) to a common earth ground.