Datalogic Scanning DS4600A User Manual

Page of 63
INSTALLATION 
2.3.2 
Main Serial Interface 
 
The signals relative to the following serial interface types are available on the 
input/output connector of the DS4600A. 
 
The main serial interface type and its relative parameters (baud rate, data bits, 
etc.) are selected via software either using the WinHost utility program or Host 
Mode programming. For more details refer to the section "Main Interface Menu" 
in the WinHost Help On Line. 
 
Details regarding the connections and use of the main interface selection are given in 
the next paragraphs. 
 
 
RS232 Interface 
 
The serial interface is used in this case for point-to-point connections; it handles 
communication with the host computer and allows both transmission of code data 
and the configuration of the scanner. This is the default interface. 
 
The following pins of the 25-pin connector are used for RS232 interface connection: 
 
Pin Name 
Function 
2 TX232 
transmitted 
data 
3 RX232 
received 
data 
RTS232 
request to send 
CTS232 
clear to send 
SGND Main 
signal ground main interface 
 
It is always advisable to use shielded cables. The overall maximum cable length 
must be less than 15 m (49.2 ft). 
 
 
RTS/CTS HARDWARE HANDSHAKING ENABLED 
DS4600A
USER INTERFACE
7
SGND Main
SGND
RTS232
4
DCD
CTS232
5
DTR
RX232
3
TXD
TX232
2
RXD
Earth 
Ground
 
Figure 8 - RS232 Main Interface Connections