13.9.1
Online Mode
The online mode allows you to download the configuration data directly to a PC
station attached to the network (MPI, PROFIBUS or Ethernet), or to load the data
on the local PC station if you are using this as the configuration station.
station attached to the network (MPI, PROFIBUS or Ethernet), or to load the data
on the local PC station if you are using this as the configuration station.
S
Online mode - networked (engineering station networked with runtime
PC)
PC)
Download
Engineering station
Runtime PC
Use this option when the following requirements are met:
S
The PC station (runtime PC) is not the configuration station.
S
The PC station (runtime PC) is linked to the configuration station via a network.
The PC station is accessible as a communications node, for example after
setting the parameters in the initial configuration.
The PC station is accessible as a communications node, for example after
setting the parameters in the initial configuration.
S
A connection exists that can, for example, be checked using the “Accessible
Nodes” function.
Nodes” function.
Follow the steps below:
Procedure for “Downloading Project Engineering Data to the PC
Station” -
Online - Networked
Tool
1.
Check the following on the runtime PC:
S
The mode is set to online.
S
The runtime PC is not disabled.
Station
Configuration
Editor
Configuration
Editor
2.
Select the station you want to download to.
NCM PC / STEP 7
3.
Download the configuration data with PLC - > Download
If you are using PG operation: Make sure that you set the correct
interface using the Set PG/PC Interface tool (access point “S7ONLINE“).
interface using the Set PG/PC Interface tool (access point “S7ONLINE“).
NCM PC / STEP 7