Siemens C79000-G8976-C156-07 User Manual

Page of 300
16
Configuration Console Tool
207
Commissioning PC Stations - Manual and Quick Start
Release 5/2005
C79000-G8976-C156-07
Activity
2
Click the “Restart” button.
If currently possible, the module is reset. The result of the restart is displayed in the text box.
16.2.2
Forcing the OPC Server to Close Down
The OPC server for SIMATIC NET is started automatically by the operating system
when a client wants to use it. The OPC server maintains reference counters to be
able to recognize when the last registered client is closed. The OPC Server then
closes itself down. This is only possible when the clients set and reset the user
counters of the OPC Server correctly.
If a client closes down irregularly and the user counter is not reset, the OPC server
will not close down although no more clients are active. The server continues to
keep the communication connections open.
In this case, it is a good idea to stop the OPC server manually.