Cal Spas Inground Spa User Manual

Page of 40
2009 Inground Spas
LTR20091002, Rev. A
Pr
eparing f
or 
Your Ne
w Ingr
ound Spa
www.calspas.com
14
Once topside panel operation is verified. Turn off 
7. 
power,  disconnect  the  extension  loom  from  the 
circuit board and GENTLY route through conduit 
to complete installation.
NOTE: This loom and its connector are not meant to 
withstand heavy pulling. Make sure, when routing the 
extension loom and temperature sensor lines through 
conduit, you exercise extreme caution.
Once properly run through the conduit, repeat steps 
5 and 6 above.
Inground Spa Light Installation In-
structions
On  spas  ordered  with  inground  lights,  the  factory 
installs  the  light  niche  for  you.  The  next  steps  of 
installation should be performed by a qualified licensed 
electrician.
Always  read  and  follow  light  manufacturer’s  safety 
and  installation  instructions  prior  to  installation  and 
operation. Incorrect installation may damage the light 
and void its warranty.
The light circuit must be on a GFCI protected service 
(alone or with a switch).
The water resistant junction box (or for 12 volt models, 
the low voltage transformer) must be located:
at least 8” (20 cm) above water level
• 
at least 4” (10 cm) above ground level, and
• 
at least 48” (121 cm) away from the spa .
• 
See figure below.
Light  niche  and  any  metallic  items  in  a  5’  (152  cm) 
radius  must  be  properly  bonded  with  #8  AWG 
grounding wire.
Connect rigid conduit to the 3/4” hub located at 
1. 
the back of the light niche and run to a water re-
sistant junction box (or for 12 volt models to a low 
voltage transformer) no further than 25’ (7.6m). 
Remember this is a water cooled light, so the con-
duit and all connections must be leakproof.
Feed  the  light  cord  through  the  rigid  conduit  to 
2. 
the junction box, leaving at least 4 feet of cord at 
the end of the light fixture. This slack in the light 
cord will allow servicing without draining the spa 
in the future.
Wrap light cord slack around back of light housing 
3. 
and attach light to niche with mounting screw.
Cut the cord at the junction box, leaving at least 
4. 
6” (15 cm) of cord to make connections.
Strip 6” (15 cm) of the out cord jacket to expose 
5. 
the three insulated wires. Be careful not to dam-
age the insulation on the three inner wires.
Connect the three wires to the corresponding cir-
6. 
cuit wires in the junction box and secure the junc-
tion box cover in place.
Replace the light assembly in the niche and tight-
7. 
en the special pilot screw.
Fill the spa until the underwater light is completely 
8. 
submerged in water before operating the light for 
more than 10 seconds. Turn on the main switch or 
circuit breaker, as well as the spa light control, to 
check for proper operation
Important: Make sure spa light is submerged in 
at least 18” of water prior to testing .