Lucent Technologies 6000 User Manual

Page of 586
5-20
   Preliminary January 4, 2001   
MAX 6000/3000 Network Configuration Guide
Configuring Frame Relay
Concentrating incoming calls onto Frame Relay
Routing parameters in RADIUS
In addition to the attributes described in “Overview of DLCI interface settings” on page 5-13
the following attribute-value pairs must be specified in the permconn profile of a Frame Relay 
gateway:
Examples of a gateway configuration
In the following example, the MAX acts as a gateway between a client that dials in with the 
address 10.1.2.3/29, and a remote router that is reachable across Frame Relay, as shown in 
Figure 5-8:
Figure 5-8.  Frame Relay gateway
The following set of parameters configures an MP+ Connection profile for the dial-in client in 
Figure 5-8:
Ethernet
Connections
mpp-client
Name=mpp-client
Active=Yes
Encaps=MPP
Encaps options
Recv PW=clientpw
IP options
LAN Adrs=10.1.2.3/29
Following is a comparable RADIUS profile:
mpp-client Password="clientpw", User-Service=Dialout-Framed-User
    Framed-Protocol=MPP,
    Framed-Address=10.10.1.3,
    Framed-Netmask=255.255.255.248
Attribute
Value
Ascend-Route-IP (228)
Enables/disables IP routing for this connection. (IP is enabled by 
default. If this attribute is present, it must be set to Route-IP-Yes 
for Frame Relay gateway connections.)
Framed-Address (8)
Destination IP address, which lies at the end of a PVC whose first 
hop is known by the specified DLCI.
Framed-Netmask (9)
A subnet mask for Framed-Address.
10.9.8.7/24
Frame Relay
DLCI 55
10.1.2.3/29