Lucent Technologies 6000 User Manual

Page of 586
Configuring Frame Relay
Configuring the MAX as a Frame Relay switch
MAX 6000/3000 Network Configuration Guide
 
   Preliminary January 4, 2001   
5-27
Nailed Grp=111
Ethernet
Frame Relay
p130east
Name=p130east
Active=Yes
FR Type=DCE
Nailed Grp=222
The next set of parameters specifies the circuit between the two Frame Relay interfaces:
Ethernet
Connections
max6
Station=max6
Active=Yes
Encaps=FR-Cir
Route IP=No
Encaps options
FR Prof=max
DLCI=100
FR Circuit=frcir1
Ethernet
Connections
p130
Name=p130
Active=Yes
Encaps=FR-Cir
Encaps options
FR Prof=p130east
DLCI=200
FR Circuit=frcir1
Using RADIUS profiles
The following RADIUS frdlink pseudo-user profiles define the datalinks to the MAX and to 
the Pipeline 130 (P130-East):
frdlink-max-21 Password="ascend", User-Service=Dialout-Framed-User
    Ascend-FR-Profile-Name="max",
    Ascend-Call-Type=Nailed,
    Ascend-FR-Type=Ascend-FR-DCE,
    Ascend-FR-Nailed-Grp=111
frdlink-max-22 Password="ascend", User-Service=Dialout-Framed-User
    Ascend-FR-Profile-Name="p130east",
    Ascend-Call-Type=Nailed,
    Ascend-FR-Type=Ascend-FR-DCE,
    Ascend-FR-Nailed-Grp=222