Setting Up Virtual Private Networks
Configuring ATMP tunnels
MAX 6000/3000 Network Configuration Guide
 11-7
Ascend-Primary-Home-Agent=10.1.2.3,
Ascend-Home-Agent-Password="private"
Understanding the Foreign Agent parameters and attributes
This section provides some background information about configuring a Foreign Agent to 
initiate an ATMP request to the Home Agent MAX. For detailed information about each 
parameter, see the MAX Reference. For details about attributes and configuring external 
authentication, see the TAOS RADIUS Guide and Reference
Table 11-1 lists the RADIUS attributes required when the mobile client and home network are 
routing IP, and Table 11-2 lists the required attributes when the mobile client and home 
network are routing IPX. Descriptions of the attributes follow the tables.
Parameter(s)
Usage
ATMP Mode
For the Foreign Agent, the mode is Foreign, which makes 
the Type, Password, and SAP Reply parameters not 
applicable.
UDP Port
ATMP uses UDP port 5150 for ATMP messages between 
the Foreign Agent and Home Agent. If you specify a 
different UDP port number, make sure that the entire ATMP 
configuration agrees.
GRE MTU
Specifies the Maximum Transmission Unit (MTU) for the 
path between the Foreign Agent and Home Agent (as 
described in “Setting an MTU limit” on page 11-3).
ATMP SNMP Traps
Specifies that the MAX sends ATMP-related SNMP traps.
IP configuration and Connection 
profile parameters
The cross-Internet connection to the Home Agent is an IP 
routing connection that the MAX authenticates and 
establishes in the usual way. (For details, see Chapter 9, 
“Configuring IP Routing.”)
RADIUS authentication 
attributes
The Foreign Agent must use RADIUS to authenticate 
mobile clients, and the RADIUS server must be running a 
version of the daemon that includes the ATMP attributes. 
(For details, see the TAO RADIUS Guide and Reference.) 
RADIUS user-profile attributes The RADIUS user profiles for mobile clients must include 
ATMP attributes. The required attributes differ slightly, 
depending on whether the mobile client and home network 
run IP or IPX and whether the Home Agent MAX operates 
in router mode or gateway mode.
Table 11-1.Required RADIUS attributes to reach an IP home network
Home Agent in router mode
Home Agent in gateway mode
Ascend-Primary-Home-Agent
Ascend-Primary-Home-Agent
Ascend-Home-Agent-Password
Ascend-Home-Agent-Password