Configuring WAN Access
Configuring T1 lines
MAX 6000/3000 Network Configuration Guide
 3-9
If you set Sig Mode to Inband signaling (also called robbed-bit signaling), you must set the 
Rob Ctl parameter to specify a call-control mechanism. For additional information, consult 
your carrier. 
Switch-specific settings
Set the Switch Type parameter to specify the network switch providing ISDN service on the 
T1/PRI line. The carrier supplies the setting. You must also specify the physical layer frame 
format for the T1 line by setting the Framing Mode parameter.
Front-end settings
The Front End parameter specifies the type of Channel Service Unit (CSU) used for the T1 
line. Your carrier can assist you in setting the Encoding parameter. This parameter specifies the 
Layer-1 line encoding used for physical links, which affects the way the digital signals on the 
line represent data. Set the Length parameter if you are using an external CSU. If using the 
internal CSU, ask your carrier about a value, if any, for the Buildout parameter. 
Monitoring line quality
The telephone company uses a Facilities Data Link (FDL) protocol to monitor the quality and 
performance of T1 lines. In a line’s subprofile, set the FDL parameter to specify the protocol. 
If you are not sure which FDL protocol to specify, your telephone carrier can tell you.
Supporting PBX connections
In a MAX 3000 unit’s T1 slot, or in either T1 slot of a MAX 6000, you can connect line 2 to a 
PBX. The unit can act as a switch, moving an incoming call from line 1 to line 2. You can 
assign the PBX a number for dialing out through the MAX unit. If the second line’s signaling 
mode is PBX T1, you can route calls to the PBX. For all calls received by the PBX, you can 
specify a sample count to provide accurate tone detection and decoding. To support PBX 
connections, you set the following parameters in the Net/T1 > Line Config > Line Config 
profile > Line N subprofile:
Parameter
Specifies
PBX Type
The type of signaling to be used with the PBX on line 2.
Delete Digits
The number of digits to be deleted from the beginning of the dialed 
number when changing the number so that the PBX on line 2 can dial out 
through the MAX unit.
Add Number
A series of digits to be added to the beginning of the dial-out telephone 
number after the digits specified by Delete Digits have been removed. 
Ans #
A telephone number to be used for routing calls received on the first T1 
line to the device terminating the second T1 line when the second line’s 
signaling mode is PBX T1. The answer number is one of the unit’s 
telephone numbers. (For more information, see “Configuring inbound 
calls” on page 3-59 an
d “Configuring outbound calls” on page 3-69.)