Lucent Technologies 6000 User Manual

Page of 586
3-10
MAX 6000/3000 Network Configuration Guide
Configuring WAN Access
Configuring T1 lines
For detailed information about each parameter, see the MAX Reference.
Configuring carrier-specific services 
To enable the MAX to communicate with your carrier’s switch, and vice versa, obtain values 
for the Call-by-Call, T1-PRI:PRI # Type, and T1-PRI:NumPlanID parameters from your 
service provider. The value specified for the Call-by-Call parameter sets the signaling value for 
routing calls. The T1-PRI:PRI # Type and T1-PRI:NumPlanID parameters specify values that 
the MAX unit applies to outbound calls on PRI lines so that the switch can properly interpret 
the telephone number dialed. 
To configure carrier-specific services, open the Net/T1 > Line Config profile > Line N 
subprofile for the line you are configuring and set the following parameters:
For detailed information about each parameter, see the MAX Reference.
Using MAXDAX
MAXDAX enables you to route incoming calls from T1 or PRI lines to specific outgoing 
channels on the same or different T1 or PRI lines. To implement MAXDAX, you must set 
parameters in the Net2Net Incoming Calls and Net2Net ChanGroup ID profiles. In the 
Net2Net Incoming Calls profile, you define parameters used in configuring channels on which 
the MAX unit receives incoming calls. In the Net2Net ChanGroup ID profile, you define 
parameters used in configuring channels for outbound calls. 
For complete information about MAXDAX, see “Configuring MAXDAX” on page 3-74. Or, 
for detailed information about each parameter, see the MAX Reference.
Ans Service
A data service (voice, for example). Any call that uses the specified data 
service will be routed to line 2. This parameter can be used as an 
alternative to Ans # when the second line’s signaling mode is PBX T1. 
(For more information, see “Configuring inbound calls” on page 3-59 
and “Configuring outbound calls” on page 3-69.)
Input Sample 
Count
Number (one or two) of sets of Goertzel samples the PRI-T1 conversion 
process is to use for DTMF tone detection. By default, the MAX uses 
only one sample to decode signals from robbed-bit PBXs, because some 
PBX devices have a tone duration of less than 50ms, which does not 
provide enough time to compute two sets of Goertzel samples. The 
PRI-T1 conversion process is more accurate when the MAX can use two 
samples. Using two samples is recommended when the tone duration is 
longer than 70ms.
Parameter
Specifies
Call-by-Call
Service provider’s call-by-call signaling value for routing calls from a 
local device to the carrier’s network through the MAX unit.
T1-PRI:PRI # Type
TypeOfNumber field in the called party’s information element.
T1-PRI:NumPlanID NumberPlanID field in the called party’s information element.