Nortel Networks 1005r User Manual
RAID operations
Standard 1.10
150
CallPilot
1
Restart the server and enter the Ctrl+M utility when prompted
during system bootup.
during system bootup.
2
From the Management menu, select Objects and press Enter.
3
Select Objects > Physical Drive and press Enter.
4
Select FAIL Drive for the drive that is online (A01-1-Onln).
Result: The drive shows as failed.
5
Select the second drive (previously taken offline as the backup drive
and marked failed) and make it ONLINE. Ignore the warning
message.
and marked failed) and make it ONLINE. Ignore the warning
message.
Result: The second drive is marked ONLINE and the first drive is
marked failed.
marked failed.
6
Exit the utility and press Ctrl+Alt+Delete to reboot the server.
Result: The system boots up to the original configuration before the
PEP installation.
PEP installation.
7
When the system is fully booted, open the Windows MegaRAID
console and rebuild the failed drive using the same process
described in “To synchronize the RAID after a successful PEP
installation,” on page 149.
console and rebuild the failed drive using the same process
described in “To synchronize the RAID after a successful PEP
installation,” on page 149.
Result: The system is now in the original configuration.
ATTENTION
Do not use the Power Console for the following procedure,
or data corruption can occur.
or data corruption can occur.