Nortel Networks 1005r User Manual

Page of 206
RAID operations
Standard 1.10
150
CallPilot
1
Restart the server and enter the Ctrl+M utility when prompted 
during system bootup.
2
From the Management menu, select Objects and press Enter.
3
Select Objects > Physical Drive and press Enter.
4
Select FAIL Drive for the drive that is online (A01-1-Onln). 
Result: The drive shows as failed.
5
Select the second drive (previously taken offline as the backup drive 
and marked failed) and make it ONLINE. Ignore the warning 
message. 
Result: The second drive is marked ONLINE and the first drive is 
marked failed.
6
Exit the utility and press Ctrl+Alt+Delete to reboot the server. 
Result: The system boots up to the original configuration before the 
PEP installation. 
7
When the system is fully booted, open the Windows MegaRAID 
console and rebuild the failed drive using the same process 
described in  “To synchronize the RAID after a successful PEP 
installation,” on page 149.
 
Result: The system is now in the original configuration.
ATTENTION
Do not use the Power Console for the following procedure, 
or data corruption can occur.