Enterasys Networks CM Version 1.0 User Manual

Page of 38
Installing the DC Power Supply
1-10
DC Power Supply Installation
3.
Remove the tape seal on the non‐conductive bag to remove the module.
4.
Perform a visual inspection of the power supply and cable harness for any signs of 
physical damage. Contact Enterasys Networks if there are any signs of damage. Refer 
to 
”  on page xv for details.
Installing the DC Power Supply
When you receive your Enterasys Matrix™ X chassis, a coverplate will be in place over all 
power supply slots except PS1. This slot is left open for your convenience when installing 
the first power supply.
Power supplies are installed in slots located along the right‐front side of Enterasys 
Matrix™ X16‐C and X8‐C chassis, or along the bottom of the Enterasys Matrix™ X4‐C 
chassis. The location of the power supply slots in the Enterasys Matrix™ X8‐C chassis is 
shown in 
. If you intend to install only a single power supply, it can be installed 
in any of the power supply slots, although slot PS1 is left open for your convenience.
A Phillips screwdriver is required to install the DC Power Supply in an Enterasys 
Matrix™ X chassis.
To install DC power supplies in your Enterasys Matrix™ X chassis:
1.
Attach the ESD wrist strap shipped with your Enterasys Matrix™ X chassis to your 
wrist and plug the cable from the ESD wrist strap into the ESD grounding receptacle 
on your chassis.
Table 1-4
Contents of X-DC Carton
Item
Quantity
X-DC power supply
1
Plastic bag containing 5 nuts, 5 lock washers, and two 2-hole 
compression lugs.
1
Enterasys Matrix X Router DC Power Supply Notice
1
Caution: To prevent equipment damage, do not install AC and DC power supplies in the 
same chassis.
Precaución: Para evitar que el equipo se dañe, no utilice las fuentes de poder CC y CA 
en el mismo chasis.
Note: The illustrations for the following procedure use the Enterasys Matrix™ X8-C 
chassis. The procedure is the same for the Enterasys Matrix™ X16-C and Enterasys 
Matrix™ X4-C chassis, although the location of the power supply slots is different for the 