Enterasys Networks X16-C User Manual

Page of 94
LEDs and Reset Button
3-42 Matrix X16-C Chassis Setup
LEDs and Reset Button
The following sections describe LED indications for the following:
Power supplies and fan trays
IOM, CM, and FMs (with CM Reset button)
Power Supply LEDs
Two LEDs are provided on the power supply module: a DC LED indicating the operational status 
of outgoing power and an AC LED indicating incoming AC line voltage is sufficient or has fallen 
below operational limits. Refer to 
 for their location and 
 for a description of 
LED function. Power supplies are installed in chassis slots PS1 through PS6 along the right‐hand 
side of the chassis.
Figure 3-36  Power Supply LEDs
Intake cooling fans
DC Power LED 
Handle
AC Power LED
3
4
2
1
Table 3-1 DC/AC Power Supply (PS1-PS6) LED Definitions
Function
LED Activity
DC Power LED
Power supply successfully providing 48 VDC to the system
Green
Power supply malfunctioning
Off
AC Power LED
Sufficient AC power supply (influx)
Green
No AC power into the module
Off