Overview of DFE-Platinum Module Shutdown Procedure
Matrix DFE-Platinum Series Installation Guide 4-5
Overview of DFE-Platinum Module Shutdown Procedure
The DFE‐Platinum module must shut down in an orderly fashion to ensure that the other modules 
in the system and other devices on the network are notified of the impending change. The devices 
can then make intelligent decisions and stabilize the network before the change is made; thereby 
increasing network availability.
You can shut down a DFE‐Platinum module in an operating system using the 
OFFLINE/RESET 
switch
 shown in 
. There are two procedures to shut down a DFE‐Platinum module.
Figure 4-2  OFFLINE/RESET Switch
User parameters 
(IP address, device 
and module name, 
etc.) were lost 
when the module 
power was cycled, 
the front panel 
OFFLINE/RESET 
switch was 
pressed.
Position of Mode switch (7), 
Persistent Data Reset, was 
changed sometime before 
either cycling power or 
pressing the OFFLINE/
RESET switch, causing the 
user-entered parameters to 
reset to factory default 
settings.
Clear Persistent Data that 
was set through Local 
Management.
The module was moved 
either from slot-to-slot or 
from chassis-to-chassis.
Reenter the lost parameters as necessary. Refer to the 
Enterasys Matrix DFE-Diamond/Platinum Series 
Configuration Guide
 for the instructions to configure 
the device.
If the problem continues, contact Enterasys Networks 
for technical support.
Table 4-2 Troubleshooting Checklist  (continued)
Problem
Possible Cause
Recommended Action
Caution: Do not remove a DFE module from an operating chassis system before reading the 
following information and instructions.
Precaución: Antes de retirar los módulos DFE del chasis en funcionamiento, lea las siguientes 
instrucciones y la información suministrada.
OFFLINE/RESET switch
COM
OFFLINE/
RESET
MGMT
CPU
1
2
GROUP
SELECT
1X
11X
12X
G
R
O
U
P
1
GROUP
1
2
3
4
5
6
7
8
9
10
11
12
2G4082-25
Gb ENET
À