Network Parameters
Serial Data Bits: This is a read-only field and displays the number of data bits used in serial communication 
(8 data bits by default).
Serial Parity: This is a read-only field and displays the number of parity bits used in serial communication 
(no parity bits by default).
Serial Stop Bits: This is a read-only field that displays the number of stop bits used in serial communication 
(1 stop bit by default).
NOTE
The serial port bit configuration is commonly referred to as 8N1.
Network Time Protocol (NTP)
The Network Time Protocol (NTP) is a protocol that synchronizes computer clocks over the Internet. Devices that 
support NTP contact a known public time server to periodically retrieve the correct date and time. See 
 for more information on this protocol.
By default, the AP boots up using January 1, 1970 as the date and 00:00:00 as the time. The AP does not necessarily 
need the correct date and time but you may want to the AP to report the correct date and time if you intend to enable 
the 
 (Syslog) or 
 functionality. Note that the AP’s 
 alarms are reported in 
terms of the AP’s Up Time and not in terms of standard date and time.
From the NTP Server Configuration screen, you can configure the AP-2500 to contact a network time server to 
retrieve the correct time and date each time the AP is turned on or rebooted. By default, NTP is disabled. If you want to 
the AP to use the Network Time Protocol (NTP) to retrieve the time over the Internet, keep in mind the following:
The AP will only contact a time server during boot-up. Therefore, you need to reboot the AP after configuring this.
The AP must have a connection to the Internet to retrieve the date and time.
— If the AP cannot communicate with a time server during boot-up, it will generate a major severity alarm, 
which is reported in the 
 screen as “No response from SNTP server.” SNTP stands for 
Simple Network Time Protocol (a simplified version of the Network Time Protocol defined in RFC 2030 at 
). 
See 
 to identify the IP addresses for public time servers in your area.
You can also manually set the date and time from the NTP Server Configuration screen. However, if NTP is disabled, 
the AP will revert back to its default time (January 1, 1970 00:00:00) the next time it is rebooted (in other words, the AP 
does not store the date and time in non-volatile memory).
See 
 for step-by-step instructions for configuring the NTP parameters.
Filtering
The Access Point’s Packet Filtering features help control the amount of traffic exchanged between the wired and 
wireless networks. There are two sub-categories under the Filtering heading.
Ethernet Protocol
The Ethernet Protocol Filter blocks or forwards packets based on the Ethernet protocols they support. 
Follow these steps to configure the Ethernet Protocol Filter:
1. Configure the Ethernet Protocol Filter Table. This table is pre-populated with existing Ethernet Protocol Filters, 
however, you may enter additional filters by specifying the appropriate parameters.
To add an entry, click Add, and then specify the Protocol Number and a Protocol Name
— Protocol Number: Enter the protocol number. Se
 
for a list of protocol numbers.
— Protocol Name: Enter related information, typically the protocol name.