Trendnet TPL406E2K User Manual

Page of 30
 
 
 
 
 
 
 
 
  
 
© Copyright 2012 TRENDnet. All Rights Reserved. 
 
 
 
 
TRENDnet User’s Guide
 
TPL-406E / TPL-406E2K 
 
23
 
Appendix 
 
Using the Sync Button with other TRENDnet Powerline models 
 
A different Sync button procedure may be required depending on the TRENDnet 
Powerline model adapter(s) you are using. 
 
If you are using one of the Powerline models listed in the table below, you will need to 
use the Sync button procedure provided on the next page to connect to TRENDnet 
models TPL-303E, TPL-304E, TPL-308E, TPL-309E, TPL-311P, TPL-406E, or TPL-407E. 
 
Model 
TPL-405E  
TPL-401E  
TPL-402E  
TPL-305E  
TPL-310AP  
TPL-306E  
TPL-307E  
 
If you are using an older firmware version on your Powerline adapter, it is 
recommended for you upgrade to the latest firmware version to ensure the latest fixes 
To check if firmware updates are available for your Powerline adapter, check your 
Powerline model
  
To change the default encryption key between two Powerline adapters: 
 
Note: Assuming one Powerline adapter is a model listed in the table and the other 
Powerline adapter being the TPL-303E, TPL-304E, TPL-308E, TPL-309E, TPL-311P, TPL-
406E, or TPL-407E. 
 
In this example, the procedure below will reference how to connect a TPL-306E to a TPL-
406E Powerline adapter using the Sync button. The TPL-306E can be replaced with any of 
the models in the table and the TPL-406E can be replaced with the TPL-303E, TPL-304E, 
TPL-311P, or TPL-407E when following this procedure. 
 
1. On the TPL-306E, push and hold the Sync button for 15 seconds and release it. All 
LEDs will turn off and turn back on. This will erase the current encryption key assigned 
for this Powerline adapter. 
Note: If the Powerline adapters were connected prior using the default encryption key, 
once you complete this step, the TPL-406E Powerline adapter will not be able to 
communicate to the TPL-306E Powerline adapter. 
 
2.  Afterwards, push and hold the Sync button on the TPL-306E for 2 seconds and 
release it. The Power (PWR) LED will start blinking. This will initiate the Sync process and 
generate a random encryption key. 
 
3. Within 2 minutes, push and hold the Sync button on the TPL-406E for 3 seconds and 
release it. The Power (PWR) LED will start blinking. This will negotiate a connection 
between both Powerline adapters using the new encryption key. All LEDs will turn off 
and turn back on and the Powerline (PL) LED will turn on the when adapters are 
connected.