Siemens SM2 monitoring system User Manual

Page of 500
332
U3585-J-Z125-8-76
SELECTED HOSTS
SM2 information screens
SELECTED HOSTS
This screen displays the hosts which were selected by means of the SELECT-HOSTS
statement.
The output can only be requested in the administration facility using the
SHOW-SELECTED-HOSTS statement.
Information on the selected hosts
HOST-NAME
Name of the host
PROCESSOR-NAME Processor name from the point of view of the local host
(for information on host and processor names, see the note in the
description of the SELECT-HOSTS statement on page 110)
LAST BUFFER
Time stamp of the last monitoring data called; this time stamp is
identical to the time in the top right-hand corner of the reports
RSLT NOT VALID means that no (up-to-date) data is available.
Possible reasons:
No data has been requested.
Data has been requested but not transferred because the
monitoring cycle on the addressed host was not yet terminated
or the transfer was unsuccessful.
D016ZE04 SM2 SELECTED HOSTS                                  99-03-24  14:29:30
     HOST-NAME      PROCESSOR-NAME         LAST BUFFER
     *LOCAL         D016ZE04               14:28:00
     D016ZE02       D016ZE02               14:29:00
     D016ZE07       D016ZE07               14:29:00