CHANNEL-IO
SM2 monitoring programs
Example 2
REMOVE-BCAM-CONNECTION-SET SET-NAME = *ALL
SET-BCAM-CONNECTION-PARAMETER
ADD-BCAM-CONNECTION-SET
SET-NAME = setname2,
CONNECTION-SELECTION = *BY-PORT-NUMBER(
PORT-NUMBER = *SPECIFIED (
LOCAL-PORT-NUMBER   = 5000,
PARTNER-PORT-NUMBER = *ANY)),
CONNECTION-TYPE = *BOTH,
HOST-SELECTION  = *SPECIFIED (
LOCAL-HOST-NAME = *LOCAL,
PARTNER-HOST-NAME = hostname2)
CHANGE-MEASUREMENT-PROGRAM TYPE = *BCAM-CONNECTION
These statements end the current monitoring process and restart it using new parameters.
The bucket parameters are set to their default values. A connection set is defined which
records all connections with the local port number 5000 and which lead to the specified
host.
CHANNEL-IO
Monitored data on the channel load
The CHANNEL-IO monitoring program provides precise information on the channel load.
For each channel to be monitored, it returns the number of I/O operations for PAM block
transfer, byte transfer, and without data transfer (NODATA). In addition, it indicates the
volume of data transferred for PAM block and byte transfer in PAM blocks.
CMS
Monitored data on the catalog management system
The CMS monitoring program provides information on the performance of the catalog
management system. It outputs monitored variables for each catalog and for all private
disks.