Hitachi CP-WU8450 User Manual

Page of 33
32
7. Troubleshooting
About the phenomenon confused with a machine defect, check and cope with it 
according to the following table.
Phenomena that may be easy to be mistaken for machine defects
Phenomenon
Cases not involving a machine defect
Reference
page
Intellectual 
Stack does not 
function.
No power is supplied to the Main and Sub 
projector. 
To use the Intellectual Stack feature, 
supply AC power to both the Main and Sub 
projectors.  If AC power is supplied to only 
one of the projectors, Intellectual Stack is 
disabled.  
8
 in
 User’s
     Manual 
      (concise)
The RS-232C cable between the Main and 
Sub projectors is not properly connected. 
To use the Intellectual Stack feature, connect 
an RS-232C cross cable between the Main 
and Sub projectors.  If the cable is not 
connected, the Main projector cannot control 
the Sub projector.  
8
The menu settings for Intellectual Stack 
are not performed correctly. 
Check the settings of the STACK menu on 
the Main and Sub projectors.  To use the 
Intellectual Stack feature, one projector must 
be set to Main and the other projector must 
be set to Sub.  
14
Signal cables are not connected correctly. 
Check the connection of cables.  Also check 
that the cable connection matches with the 
port settings in the menu.
24
10 - 14
 in
 Operating
     Guide
The Main and 
Sub projector do 
not operate in 
synchronization.
The RS-232C cable between the Main and 
Sub projectors is not properly connected. 
Connect the RS-232C cable properly and 
restart the Main projector.
8
(continued on next page)