3M 40800 User Manual

Page of 122
10-SAFETY DEVICES OF THE MACHINE
22 
10.1  Blade Guards
Both the top and bottom taping units have a blade 
guard.  (See Manual 2:  
AccuGlide™ 3 Taping 
Heads - 2 Inch).
10.2  Emergency Stop Button
The box drive belts are turned on and off with the 
electrical switch on the side of the machine frame.
The machine electrical supply can be turned off 
by pressing the latching emergency stop switch. 
To restart machine, rotate the emergency stop 
switch clockwise to release the switch latch.  
Restart machine by pushing the Start button
(Figure 10-1).
2011 June
700a-NA 
  Figure 10-1
•  
To reduce the risk associated with 
    hazardous voltage:
−    Position electrical cord away from foot 
    and vehicle traffi c.
WARNING
• 
To reduce the risk associated with sharp 
   blade hazards:
− 
Keep hands and fi ngers away from tape 
cutoff blades under orange blade guards. 
The blades are extremely sharp.
WARNING
10.3  Electric System / Circuit Breaker
The electric system is protected by a ground wire 
whose continuity has been tested during the fi nal 
inspection. The system is also subject to insulation 
and dielectric strength tests.
  
To reduce the risk associated with 
    mechanical and electrical hazards:
−  
Allow only properly trained and 
  qualifi ed personnel to operate and service 
  this equipment.
WARNING
The case sealer is equipped with a circuit breaker 
which trips if the motors are overloaded. Located 
inside the electrical enclosure on the side of the 
machine frame just below the machine bed, the 
circuit breaker has been pre-set amps and requires 
no further maintenance.
1.  Determine cause of overload and correct.
2.  Plug in machine.
3.  Press machine "On" (I) button to resume  
case sealing.
Circuit Breaker
If circuit is overloaded and circuit breaker trips, 
unplug machine from electrical power:
Important:  
The use of an extension cord is not 
 
recommended. However, if one is needed for 
 
temporary use, it must: 
• 
Have a wire size of 1.5mm diameter [AWG 16]
• 
Have a maximum length of 30.5m [100 ft]
• 
Be properly grounded.